APPENDIX
defective. If it is found to have a defect, data will be automatically
relocated, and the defective location is mapped out to prevent
future write attempts.
In the event of an unrecoverable read error, the error will be re-
ported to the host and the location will be agged as being po-
tentially defective. A subsequent write to that location will initiate
a sector test and relocation should that location prove to have
a defect. Auto Reassign Sector does not affect disk subsystem
performance because it runs as a background task. Auto Reassign
Sector discontinues when the operating system makes a request.
Consistency Check
A consistency check is a process that veries the integrity of re-
dundant data. To verify RAID 3, 5, 6, 30, 50 or 60 redundancy, a
consistency check reads all associated data blocks, computes par-
ity, reads parity, and veries that the computed parity matches
the read parity.
Consistency checks are very important because they detect and
correct parity errors or bad disk blocks in the drive. A consistency
check forces every block on a volume to be read, and any bad
blocks are marked; those blocks are not used again. This is criti-
cal and important because a bad disk block can prevent a disk
rebuild from completing. We strongly recommend that you run
consistency checks on a regular basis—at least once per week.
Note that consistency checks degrade performance, so you should
run them when the system load can tolerate it.
Data Protection
• Battery Backup
The RAID controllers are armed with a Battery Backup Module
(BBM). While a Uninterruptible Power Supply (UPS) protects most
servers from power uctuations or failures, a BBM provides an
additional level of protection. In the event of a power failure, a
BBM supplies power to retain data in the RAID controller’s cache,
thereby permitting any potentially dirty data in the cache to be
ushed out to secondary storage when power is restored.